BP8PPressure Transmitter
Features
- Oil-filled isolated sensor with stainless steel isolation diaphragm, wide range of applications
- ASIC technology with digital compensation
- Compact size, suitable for industrial OEM equipment
- Optional RS485 output with Modbus-RTU protocol
Request a quote View datasheetDownload PDFBuild an ordering code
Measuring range
0–5 kPa to 0–70 MPa, gauge, sealed gauge or absolute
Applications
Fluid pressure measurement in monitoring and control systems for water treatment, water supply, pharmaceutical equipment, petrochemical equipment, light industry and food, and pneumatic equipment.
Specifications
| Range | 0–5 kPa to 0–70 MPa, gauge, sealed gauge or absolute (range specified by the customer) |
|---|---|
| Overpressure | Up to 2 × the upper range limit |
| Accuracy class | 0.25 %; 0.5 % (0.5 % only for ranges below 10 kPa or above 10 MPa) |
| Operating temperature | −20 to +85 °C |
| Compensated temperature range | 0 to 50 °C |
| Temperature effect | 0.025 %/°C typical |
| Stability | Below 0.5 % FS per year |
| Output signals | 4–20 mA 2-wire; 0–5 V, 1–5 V, 0.5–4.5 V, 0–10 V 3-wire; ratiometric (10–90 %) × supply; RS485 (Modbus RTU) |
| Load | Current output: load below (supply − 12 V) / 0.02 A; voltage output: load above 10 kΩ |
| Pressure port material | SS304; other materials optional |
| Sensing diaphragm | SS316L |
| O-ring | FKM or other |
| Housing material | SS304 |
| Electrical connection | GDS angled connector 175301-803C (form A); GDM angled connector 175301-803A (form B); cable outlet, 1.5 m (form C); M12 connector with 1.5 m cable (form D); GX12 3-pin aviation connector, straight, 1.5 m cable (form G) |
| Ingress protection | IP65 (IP54 with display) |
| Weight | About 160 g (about 240 g with display; without cable) |
Accuracy is measured at 20 °C, includes linearity, repeatability and hysteresis, and is calculated by the BFSL least-squares method.
Build an ordering code
Choose each item from the datasheet's ordering table. The code updates as you go and can be sent to us as it is.
Datasheet example BP8PB0GC0100KGD-0I4
- For form D, state whether the M12 connector is straight or angled.
- A display is available on forms B, C, D and G only.
- For voltage output with a 5 Vdc supply, state "power supply 5 VDC" when ordering.
- With RS485 output there is no 4–20 mA signal; on form G the GX12 connector is 4-pin.
Related models in the selection guide
Datasheet preview
3 pages, in Chinese. Select a page to enlarge it.
Tell us the medium, range and connection
We reply with a suitable model and a quotation. Pressure port, output signal and cable length can be made to suit your equipment.
BP8PA0
BP8PB1