BP8G-BCTMiniature Pressure Transmitter
Features
- Ultra-small size, particularly suitable for small equipment
- Strong overpressure resistance, high safety
- High-purity ceramic sensing diaphragm; stable and reliable
- Waterproof and dustproof, IP67
Request a quote View datasheetDownload PDFBuild an ordering code
Measuring range
0–1 MPa, 0–1.6 MPa, 0–2 MPa, sealed gauge or absolute
Applications
Fluid pressure measurement in monitoring and control systems for coffee machines, water purifiers, pumps, household booster pumps, medical gas equipment and smart water meters.
Specifications
| Range | 0–1 MPa, 0–1.6 MPa, 0–2 MPa, sealed gauge or absolute |
|---|---|
| Overpressure | Up to 2 × the upper range limit |
| Burst pressure | 5 × the upper range limit |
| Total accuracy | 1.0 % FS |
| Non-linearity | 0.5 % FS |
| Operating temperature | −20 to +85 °C |
| Compensated temperature range | 0 to 50 °C |
| Temperature effect | 0.03 %/°C typical |
| Stability | 1.0 % FS per year |
| Output signals | 0–5 V, 1–5 V, 0.5–4.5 V, 0.4–2.0 V 3-wire; ratiometric (10–90 %) × supply |
| Load | Load above 10 kΩ |
| Pressure port material | SS304; SS316L or other materials optional |
| Sensing diaphragm | Ceramic, Al₂O₃ 96% |
| O-ring | HNBR; FKM or other materials optional |
| Housing material | Same as the pressure port (epoxy potted) |
| Electrical connection | XH2.54-3P male lead, 15 cm as standard (other forms on request) |
| Ingress protection | IP67 |
| Weight | About 22 g |
Accuracy is measured at 20 °C, includes linearity, repeatability and hysteresis, and is calculated by the BFSL least-squares method.
Build an ordering code
Choose each item from the datasheet's ordering table. The code updates as you go and can be sent to us as it is.
Datasheet example BP8G-BCTSD0002MGA-0V5-P24
- O-ring is HNBR by default; FKM or other materials on request, state when ordering.
Datasheet preview
2 pages, in Chinese. Select a page to enlarge it.
Tell us the medium, range and connection
We reply with a suitable model and a quotation. Pressure port, output signal and cable length can be made to suit your equipment.